# Storage Node Installer for Windows
|
|||
|
|
|||
|
## Abstract
|
|||
|
|
|||
|
This design doc outlines how we setup Storage Node on Windows.
|
|||
|
|
|||
|
## Background
|
|||
|
|
|||
|
Currently we are using Docker to maintain Storage Nodes.
|
|||
|
Unfortunately Docker is not supported for Windows Home, which is popular OS among Storage Node Operators.
|
|||
|
Similarly, Docker ends up using more resources than running natively on Windows.
|
|||
|
|
|||
|
Therefore, it would be nice to be able to run Storage Node without Docker.
|
|||
|
|
|||
|
For an easy setup process we would need an installer that:
|
|||
|
1. Sets up Storage Node to run in background,
|
|||
|
2. sets up automatic updates and
|
|||
|
3. ensures we log everything properly.
|
|||
|
|
|||
|
We need to take care that we:
|
|||
|
* avoid triggering UAC unnecessarily,
|
|||
|
* start storage node before logging in and
|
|||
|
* restart on crashes.
|
|||
|
|
|||
|
## Design
|
|||
|
|
|||
|
The high-level idea is to create an installer using WIX and make Storage Node a Windows service.
|
|||
|
|
|||
|
### Installer
|
|||
|
|
|||
|
For creating an installer we can use WIX Toolkit.
|
|||
|
There is [go-msi](https://github.com/mh-cbon/go-msi), which helps to get us setup the basic template.
|
|||
|
We also need to ensure that we supply all the Operator information during installation.
|
|||
|
|
|||
|
To make the installer work we need to:
|
|||
|
|
|||
|
* Install [go-msi](https://github.com/mh-cbon/go-msi) on the build server.
|
|||
|
* Create a wix.json file like [this one](https://github.com/mh-cbon/go-msi/blob/master/wix.json)
|
|||
|
* Add a guid with `go-msi set-guid` to uniquely identify the process.
|
|||
|
* Ensure that binaries are signed before or during building the installer.
|
|||
|
* The wix.json should contain steps for:
|
|||
|
* adding Dashboard shortcut to the desktop
|
|||
|
* setting [service recovery properties](https://wixtoolset.org/documentation/manual/v3/xsd/util/serviceconfig.html)
|
|||
|
* configuring Storage Node Operator information:
|
|||
|
* Wallet Address
|
|||
|
* Email
|
|||
|
* Address/ Port
|
|||
|
* Bandwidth
|
|||
|
* Storge
|
|||
|
* Identity directory
|
|||
|
* Storge Directory
|
|||
|
* install storagenode binary
|
|||
|
* register storagenode as a service
|
|||
|
* adding Storage Node binary to Windows UserPath (optional)
|
|||
|
* open Dashboard at the end of the installer.
|
|||
|
* Run `go-msi make --msi your_program.msi --version 0.0.2` to create the installer.
|
|||
|
* Ensure that installer is signed by the build server.
|
|||
|
|
|||
|
### Service
|
|||
|
|
|||
|
We need to Storage Node to implement Windows service API, as shown in:
|
|||
|
|
|||
|
* Modify storage node/automatic updater startup code to implement [ServiceMain](https://docs.microsoft.com/en-us/windows/win32/api/winsvc/nc-winsvc-lpservice_main_functiona).
|
|||
|
* See [golang/sys](https://github.com/golang/sys/blob/master/windows/svc/example/service.go)
|
|||
|
* Create inbound firewall rule using the following Powershell command: `New-NetFirewallRule -DisplayName "Storj v3" -Direction Inbound –Protocol TCP –LocalPort 28967 -Action allow`
|
|||
|
|
|||
|
This means that Windows handles starting and restarting the binary in the background.
|
|||
|
|
|||
|
## Implementation
|
|||
|
|
|||
|
1) Modify the storage node startup to implement ServiceMain so that the binary is considered a Windows Service.
|
|||
|
2) Create script for registering binary as a Windows Background Service. (sc.exc command)
|
|||
|
3) Create wix.json file for building an MSI.
|
|||
|
4) Update the build process to include the creation of the MSI.
|
|||
|
5) Ensure the windows installer is working properly
|
|||
|
* Install Storage Node using msi.
|
|||
|
* Ensure binaries run on Windows startup, and it runs as a background process when not logged in.
|
|||
|
* Ensure UAC(s) is not triggered after installation.
|
|||
|
* Ensure that storage node restarts automatically after a crash
|
|||
|
|
|||
|
## Open Issues/ Comments (if applicable)
|
|||
|
|
|||
|
* Consider writing an uninstaller.
|
|||
|
* How do we prevent UAC from triggering?
|
|||
|
* Consider using wix without go-msi.
|